Description
With its precision, reliability, and ease of use, the Fluke 3000 FC Wireless Multimeter has all the essential electrical and electronic troubleshooting features professional technicians need. It gives you true-RMS voltage and current measurements, 6000-count resolution, manual and automatic ranging, plus a frequency, capacitance, resistance, continuity and diode measurements.
Features:
- Full featured multimeter that also reads results wirelessly from remote Fluke Connect® wireless modules
- Measures AC and DC voltage to 1000 V, AC and DC current, and temperature
- Shows up to four readings simultaneously on a bright white backlit display
- Sends measurement data to your smartphone
- Safety rated CAT III 1000 V, Cat IV 600 V; IP54
Specifications:
- AC Range / resolution:
- 600.0 mV / 0.1 mV
- 6.000 V / 0.001 V
- 60.00 V / 0.01 V
- 600.0 V / 0.1 V
- 1000 V / 1 V
- AC Accuracy:
- 45 Hz to 500 Hz: 1.0% + 3
- 500 Hz to 1 kHz: 2.0% + 3
- mV Range / resolution: 600.0 mV / 0.1 mV
- mV Accuracy: 0.09% + 2
- V Range / resolution:
- 6.000 V / 0.001 V
- 60.00 V / 0.01 V
- 600.0 V / 0.1 V
- 1000 V / 1 V
- V Accuracy:
- 0.09% + 2
- 0.15% + 2
- ))) Range / resolution: 600 Ω / 1 Ω
- ))) Accuracy: Meter beeps at < 25 Ω, beeper detects opens or shorts of 250 μs or longer.
- Ω Range / resolution:
- 600.0 Ω / 0.1 Ω
- 6.000 kΩ / 0.001 kΩ
- 60.00 kΩ / 0.01 kΩ
- 60.00 kΩ / 0.1 kΩ
- 600.0 kΩ / 0.001 MΩ
- 50.00 MΩ / 0.01 MΩ
- Ω Accuracy:
- 0.5% + 2
- 0.5% + 1
- 1.5% + 3
- Diode test:
- Range / resolution: 2.000 V / 0.001 V
- Accuracy: 1% + 2
- µF Range / resolution:
- 1000 nF / 1 nF
- 10.00 μF / 0.01 μF
- 100.0 μF / 0.1 μF
- 9999 μF1 / 1 μF
- µF Accuracy:
- 1.2% + 2
- 10% typical
- mA AC (45 Hz to 1 kHz) Range / resolution:
- 60.00 mA / 0.01 mA
- 400.0 mA3 / 0.1 mA
- mA AC (45 Hz to 1 kHz) Accuracy: 1.5% + 3
- mA DC Range / resolution:
- 60.00 mA / 0.01 mA
- 400.0 mA3 / 0.1 mA
- mA DC Accuracy: 0.5% + 3
- Frequency Range / resolution:
- 99.99 Hz / 0.01 Hz
- 999.9 Hz / 0.1 Hz
- 9.999 kHz / 0.001 kHz
- 99.99 kHz / 0.01 kHz
- Frequency Accuracy1: 0.1% + 1
- mA Function Overload protection: Fused, 44/100 A, 1000 V FAST Fuse
- mA Function Overload: 600 mA overload for 2 minutes maximum, 10 minutes rest minimum
- MIN/MAX Recording Accuracy DC Functions: ± 12 counts for changes > 350 mS in duration
- MIN/MAX Recording Accuracy AC Functions: ± 40 counts for changes > 900 mS in duration
- Maximum voltage between any terminal and earth ground: 1000 V DC or AC RMS
- Ω fuse protection from A inputs:0.44 A (44/100 A, 440 mA), 1000 V FAST Fuse, Fluke specified part only
- Display (LCD):Update rate: 4/sec
- Volts, amps, ohms: 6000 counts
- Frequency: 10,000 counts
- Capacitance: 1,000 counts
- Battery type: 3 x AA Alkaline batteries, NEDA 15A IEC LR6
- Battery life: 250 hours minimum
- RF communications: 2.4 GHZ ISM Band
- RF communication range:
- Open air, unobstructed: Up to 20m
- Obstructed, sheetrock wall: Up to 6.5m
- Obstructed, concrete wall, or steel electrical enclosure: Up to 3.5m
- Operating Temperature: -10°C to 50°C
- Storage Temperature: -40°C to 60°C
- Temperature coefficient: 0.1 X (specified accuracy) / °C (< 18°C or > 28°C)
- Relative humidity:
- 0% to 90% (0°C to 35°C)
- 0% to 75% (35°C to 40°C)
- 0% to 45% (40°C to 50°C)
- Operating Altitude: 2,000 m
- Storage Altitude: 12,000 m
- Electromagnetic compatibility – EMI, RFI, EMC, RF
- EN 61326–1:2006, EN 61326–2–2:2006
- ETSI EN 300 328 V1.7.1:2006, ETSI EN 300 489
- V1.8.1:2008
- FCC Part 15 Subpart C Sections 15.207, 15.209, 15.249
- FCCID : FCC: T68–FDMMBLE IC: 6627A–FDMMBLE
- Safety compliance:
- ANSI / ISA 61010–1 / (82.02.01): 3rd edition
- CAN / CSA-C22.2 No 61010-1-12: 3rd edition
- UL 61010–1: 3rd edition
- IEC / EN 61010–1:2010
- Certifications: CSA, FCC, CE
- Ingress Protection (IP) rating: IP54
- Pollution Degree: 2
- Dimensions (L x W x H): 207mm x 93mm x 47.5mm
- Weight: 0.34kg
Warranty:
- 3 Years Warranty Covered By Fluke

Reviews