Product Recalls
Milwaukee Tool M18 FUEL Top Handle Chainsaw – 12” and 14” models Milwaukee Tool (Australia)
PRA2026/20890
Date published: 8th May 2026
SAFETY RECALL


Dates Available for Sale:
12 May 2023 to 7 May 2026
Affected Serial Numbers:
- Electric chainsaw for cutting wood
- Available in 12” and 14” models
- Sold individually and as part of kit including a battery and charger
- Affected chainsaws have 4670 11 or 4670 21 listed as the first 6 digits of the product serial number
- The serial number can be found on the rating plate as per the image below

Defect:
The chain brake may not activate correctly if woodchips or debris accumulate, and the chainsaw is not cleaned and maintained regularly as per the manufacturer’s instructions.
Hazard:
Risk of serious injury from laceration if the chain brake does not activate during a kickback. Incidents have occurred overseas.
What Consumers Should Do:
- Stop using the product immediately.
- Contact Milwaukee Tool (Australia) for a free service and repair
- Do not take the product back to the place of purchase. If the product was purchased as part of a kit, no action is required for batteries or chargers sold with the kit.
Contact Details:
Visit: www.milwaukeetool.com.au/productnotification-top handle-chainsaws.html
Chemtools CT-BCNF-400 400g Non-Flammable Brake & Parts Cleaner
Date published: 24th June 2025
PRECAUTIONARY MEASURE

Affected Batch Numbers:
- 0603
- 1713
- 1603
- 3003
- 2333
- 0324
- 0454
- 0734
- 1574
Defect:
Chemtools are issuing a precautionary product recall for specific batches of our Brake Cleaner Non-Flammable (BCNF) due to a potential manufacturing issue that may affect the pressure in the cans, causing a couple to combust. The batches effected are 1-2+ years old and there are no issues if the can was purchased close to manufacture date and used.
Hazard:
As part of our commitment to quality and safety, we have identified that the above batches may not meet our strict formulation standards. The issue has been addressed and the formula changed as this only becomes an issue if old cans sit around for a long time. This recall is being undertaken as a precautionary measure.
Action:
- Check the batch number printed on the can.
- If your product matches any of the batch numbers listed above, please:
- Isolate the product from use or sale
- Contact our customer service team with a picture of the can with batch number visible to arrange a credit
- Dispose of the can
What should consumers do?
Contact Details:
Email: sales@chemtools.com.au
Chemtools sincerely apologise for any inconvenience caused and appreciate your cooperation in this matter. Maintaining the highest standards in product safety and customer satisfaction remains our top priority.
Makita DGP180ZBK 18V Li-ion Cordless 450g Grease Gun – Skin Only
PRA2025/20479
Date published: 28th March 2025
SAFETY RECALL

Date Sold:
Since 25th February 2021
Defect:
Hose Set 1200 (191W58-9) and Hose Set 600 (191W59-7) which are used with the 18V DGP180ZBK Grease Gun are non-compliant in accordance with ISO 1402.
Hazard:
Repeatedly bending the tip of the hose to inject grease into narrow spaces can cause a hole to form near the tip of the hose, potentially leading to grease spraying out. It may cause serious personal injurity to the operator if the correct protective equipment isn’t used.
Action:
Makita recommends customers immediately stop using the 18V DGP180ZBK Grease Gun.
Remove any grease from the barrel and return the entire tool to your nearest Makita Factory Service Centre (FSC) for a replacement of the affected parts at no charge.
What should consumers do?
Use the following link to find your nearest Makita FSC – Factory Service Centres – Makita Australia.
Contact our enquiries team on 1300 361 690 (8am-5pm AEST) for assistance in locating
your nearest Makita FSC or if you have any further questions or concerns.
Chicago HUSH Series Air Compressor
PRA: 2024/20380
Date published: 9th December 2024
SAFETY RECALL
Models:
| HUSH50 – 50 Litre | HUSH70 – 70 Litre | HUSH100 – 100 Litre | HUSH150 – 150 Litre |
![]() | ![]() | ![]() | ![]() |
Purchased between:
13/10/2021 -02/12/2024
Defect:
The insulation on the wiring under the compressor motors is inadequate and may expose live wires.
Hazard:
Risk of serious injury or death due to electrocution from contact with the live wires.
Action:
Stop using the product and unplug it from electrical supply immediately.
Return your product to a Sydney Tools store to have it inspected and repaired where needed.
Please contact recall@sydneytools.com.au for further assistance
Chervon Australia Pty Ltd – EGO Power+ Cordless Brushless Hedge Trimmer
PRA No: 2023/19853
Date published: 20th March 2024

Product Description:
A cordless hand-held brushless hedge trimmer. The hedge trimmer has a grey body with black and green detailing, green trigger switch on the black handle and a 24-inch (61 cm) blade.
Recalled hedge trimmers could have been purchased as a:
- Skin (tool only) – HT2410E
- Hedge trimmer kit (including tool, battery and charger) – HT2411E
The EGO logo is on one side of the hedge trimmer’s body and the model number HT2410 and serial number are on the opposite side.
Recalled hedge trimmers have a serial number in one of the following ranges:
- AHT04180500701X – AHT04180501300X
- AHT04180500001X – AHT04180500600X
- AHT04180600001X – AHT04180600300X
- AHT04180604951X – AHT04180605250X
- AHT04180611451X – AHT04180611750X
Where the product was sold: Nationally
Dates available for sale: March 2020 – September 2022
Recall Advertisement & Supporting documentation: Recall Notification
What are the defects?
The rear trigger switch can fail to rebound after being pressed, which can cause the hedge trimmer to activate unexpectedly.
What are the hazards?
There is a risk of serious injury including laceration if the hedge trimmer activates unexpectedly.
What should consumers do?
Stop using the recalled hedge trimmer immediately.
Consumers should contact Chervon for a free repair of the rear trigger switch.
To organise the repair, you can:
- register your details via the EGO recall portal
- phone Chervon on 1300 000 346 (select option 3) 9am to 5pm Monday to Friday
- email support@egopowerplus.com.au
Once registered, Chervon will contact consumers to direct them to the nearest repair agent to have their hedge trimmer repaired.
If you cannot return the unit to a repairer or have sold or gifted it to another person you should contact Chervon.
3M Australia Pty Limited – 3M PELTOR X4 Series Earmuffs
PRA No: 2024/20100
Date published: February 2024
Product Description: Peltor X4 Series Earmuffs
Locate the Model ID and manufacture date printed on the outside of the cup:
AT019317406, XA007707947, UU008197848, UU010818886/XA007707970, AT010613571/AT010613589
Where the product was sold: Nationally, International & Online
Manufactured Dates: March 2020 – September 2022
Recall Advertisement & Supporting documentation: Recall Notification
What are the defects?
Affected earmuffs may crack on the exterior surface of the cups and reduce the hearing protection effectiveness.
What are the hazards?
There is a risk of over-exposure to noise and possible hearing damage depending on the environment the earmuffs are used in.
What should consumers do?
Stanley Black & Decker, Inc. (SBD) – DeWalt Fiberglass Sledgehammers and Stanley FATMAX Fiberglass Sledgehammers
PRA No: 2023/19831
Date published: 27th Jul 2023
Product Description: Black and yellow fiberglass sledgehammers.
DeWalt short-handled fiberglass sledgehammers with model numbers on the head:
DWHT56024, DWHT56025, DWHT56026, DWHT56027, DWHT56029, DWHT56030, DWHT56141, DWHT56142, DWHT56147, DWHT56148
Stanley FATMAX long-handled fiberglass sledgehammers with model numbers on the handle:
FMHT56006, FMHT56008, FMHT56009, FMHT56010, FMHT56011, FMHT56019
Where the product was sold: Nationally, International & Online
Dates available for sale: 4 Aug 2014 – 30 May 2023
Recall Advertisement & Supporting documentation: Recall advertisement.pdf & Traders List – 27 July 2023
What are the defects?
The head of the sledgehammer may loosen prematurely and detach unexpectedly during use.
What are the hazards?
There is a risk of injury to the user or bystanders if the head detaches during use.
What should consumers do?
For more information, please call 1800 338 002 or visit https://www.sledgehammerrecall.expertinquiry.com/
Bayer B15A20 Heavy Duty 240V 15A 20m Extension Lead
PRA: 2023/19746
Date published: 21st April 2023
SAFETY RECALL

Purchased between:
21/02/2021 -15/02/2023
Defect:
The connections on the plug of the extension cord may become loose. This can result in overheating or fire.
Hazard:
There is a risk of serious injury caused by fire or burns.
Action:
Consumers should immediately stop using the extension lead and return the affected products to the place of purchase for a full refund.
For more information contact Sydney Tools on customerservice@sydneytools.com.au or by phone on 02 9067 6929.
Stanley Black & Decker Australia Pty Ltd t/as DeWalt — DeWalt DHS780 and DWS780-XE 305mm Mitre Saws
PRA No: 2022/19537
Date published: 8 Sep 2022
Product Description: DeWalt 305mm Mitre Saws, Models DHS780 and DWS780-XE Type Number 21, Production Date Codes between 2019-33 and 2022-06
Where the product was sold: Nationally
Dates available for sale: September 2019 and July 2022
Recall Advertisement & Supporting documentation: Recall advertisement.pdf
What are the defects?
The plastic rear guard could break or come off and hit the saw blade.
What are the hazards?
If the plastic rear guard hits the rotating saw blade, fragments of the guard may hit the user or bystanders, causing injury.
What should consumers do?
Immediately stop using the product. Check the model, type number and date code to determine whether the product is impacted. If so, contact DeWalt Customer Service Team to receive a free repair kit.
The repair kit includes a new rear guard and dust deflector assembly, two new fixing screws and instructions.
Repair instructions can be found at https://sbd.hubs.vidyard.com/watch/CPmqTr1Rd5vyJSbVTU1k9N
For further information, contact DeWalt Customer Service on 1800 338 002 or email auorders@sbdinc.com
TQB Brands Pty Ltd — Tradequip Industrial Pedestal Misting Fan 650mm
PRA No: 2020/18732
Date published: 6 May 2021
Product Description: An industrial fan with misting attachment and water tank Model number 1182
Where the product was sold: Nationally
Dates available for sale: 19 September 2016 – 9 December 2020
Recall Advertisement & Supporting documentation: Recall advertisement.pdf
What are the defects?
The user has access to live parts if they disconnect the connectors to the fan, misting unit or the water pump.
What are the hazards?
Risk of electric shock, which can cause serious injury or death
What should consumers do?
Consumers should immediately stop using the product.
To register for repair or any other information regarding this recall, please contact your place of purchase. If you cannot recall your place of purchase, please email products@tqbbrands.com.au or visit https://tqbbrands.com.au/product-recall
Tooltechnic Systems (AUST) Pty Ltd — Festool Kapex KS 88 and Kapex KS 120 Mitre Saws
PRA No: 2020/18777
Date published: 30 Mar 2021
Product: FESTOOL Kapex KS 88 and Kapex KS 120 mitre saws
Description: 230V variant. Product numbers 561398, 561396 and 561288. Manufactured from early 2007 to the end of January 2010. Saws used mainly to cut wood
Where the product was sold: Nationally, International
Dates available for sale: 31 December 2007 – 30 November 2010
Recall Advertisement & Supporting documentation: Recall advertisement.pdf
What are the defects?
Some saws have been manufactured with electrical resistors and varistors that can be damaged by fluctuating voltages while connected to mains electricity. These damaged components can then become hot or start to smoulder if they continue to experience fluctuating voltage. This could also result in the saw catching fire.
What are the hazards?
Injury to the user may occur due to melted or smouldering parts or fire. Property damage could also occur.
What should consumers do?
The Kapex KS 88 and KS 120 mitre saws should be disconnected from the mains power when not in use.
Owners of potentially affected mitre saws should unplug their saw from the mains power and check whether their saw is affected by entering their saw’s part number and serial number in the online search form at https://www.festool.com/campaigns/microsites/retrofit-au#KAPEXretrofit
Owners of affected saws should contact Festool via www.festool.com/retrofit or Tooltechnic by phone on 1300 063 900 to register their details for free modification of the saw to make them safe. People who no longer own a Festool KS 120 or KS 88 mitre saw should contact Tooltechnic to provide contact details of the new owner of the saw.
Further information is available by visiting https://www.festool.com/retrofit and selecting ‘Australia’.
Yamaha Motor Australia Pty Ltd — Yamaha Model EF2000iS 2018-2019 Portable Generators
PRA No: 2019/17977
Date published: 27 Nov 2019
Product: Yamaha Model EF2000iS 2018-2019 Portable Generators
Description: Used for recreational activities such as camping, fishing and boating
Where the product was sold: Nationally
Dates available for sale: 31 July 2018 – 19 November 2019
Recall Advertisement & Supporting documentation: Recall advertisement.pdf
What are the defects?
The tank material can be too brittle allowing the tank to crack. If the fuel tank cracks, fuel could leak, increasing the risk of fire, which could result in severe injury or death.
What are the hazards?
If the unit runs for prolonged periods in an enclosed area without ventilation, carbon monoxide poisoning could occur.
What should consumers do?
The Yamaha dealer will replace the fuel tank with one that has been correctly moulded. Yamaha recommends that consumers do not operate their affected generator until this modification is performed.
For details of your local Yamaha dealer, visit https://www.yamaha-motor.com.au/find-a-dealer or call 1300 593 600.
Torin Vehicle Jack Stand T42001CA
PRA No: 2018/17239
Date published: 3 Feb 2019
Product: Torin Vehicle Jack Stand T42001CA
Description: 1.5 tonne bottle jack stand
Where the product was sold: Nationally
Dates available for sale: 31 August 2018 – 19 December 2018
Recall Advertisement & Supporting documentation: Recall advertisement.pdf (905.75KB)
What are the defects?
The product does not meet the requirements of the mandatory standard ‘Consumer Protection Notice No. 12 of 2008, Consumer Product Safety Standard for Vehicle Support Stands’.
The product was sold without the instruction manual and an incomplete label. The jack stand’s label is missing some of the required information.
What are the hazards?
If the stand is mislabelled, and does not have correct safety information, the occupant may misuse it on a different vehicle or in a way it was not designed for. Misuse may cause jack stand instability or failure. If a consumer is under the vehicle, this may lead to a vehicle collapsing causing severe injury or death.
What should consumers do?
Affected consumers should contact Sydney Tools Pty Ltd via phone 02 8199 1199 or email import@sydneytools.com.au to discuss options for remediation.
Sydney Tools will arrange to provide consumers with an instruction manual and a permanent label that they will be able to put on the product themselves, or consumers may return the product to the nearest Sydney Tools store location for these amendments to be carried out on site.
Husqvarna Australia Pty Ltd — Lawn Mower LC 141Li
PRA No: 2018/17227
Date published: 23 Dec 2018
Product: Husqvarna LC 141Li 36V Li-ion Cordless 410mm (16″) Lawn Mower – Skin Only
Description: Battery operated lawn mower – Serial number range 20173200001 to 20183200144
Where the product was sold: Nationally
Dates available for sale: 1 September 2017 – 31 October 2018
Recall Advertisement & Supporting documentation: Recall advertisement.pdf (53.84KB)
What are the defects?
When the lawn mower is in use, a short circuit in the electronic system may occur which could be caused by a possibly defective transistor in the motor control. This short circuit leads to the failure of the device and restart attempts will be unsuccessful.
What are the hazards?
If this occurs and the consumer places the lawn mower in a garage or storeroom and does not comply with the operating instructions by removing the battery, and turning the safety key to 0 or removing the key, the short circuit may persist resulting in increased electrical current flowing into an adjacent component. If so, the adjacent component may subsequently overheat and catch on fire.
What should consumers do?
Consumers should cease use of the lawn mower immediately. Affected lawn mowers can be returned to local authorised Husqvarna dealers for repairs.
For further information, consumers should contact their local Husqvarna dealer, or Husqvarna Australia Pty Ltd on technical.service@husqvarna.com.au
Makita Australia Pty Ltd — 185mm Dustless Circular Saw model 5057KB
PRA No: 2016/15653
Date published: 28 Sep 2016
Product: Makita 5057KB 1400W 185mm (7-1/4″) Fibre Cement Dustless Circular Saw
Description: Makita 185mm Dustless Circular Saw
Where the product was sold: Nationally
Dates available for sale: 1 June 2015 – 16 September 2016
Recall Advertisement & Supporting documentation: Recall advertisement.pdf (487.08KB)
What are the defects?
When cutting at a 45 degrees angle, the blade cover does not open fully. If it is forced open by the operator the blade cover may become stuck and expose the spinning blade.
What are the hazards?
An exposed blade during use poses a serious injury risk.
What should consumers do?
Check the model and serial number of your saw. If the model and serial number of your saw is within the affected range stop using the saw immediately. Contact Makita Australia Pty Ltd on 1300 361 690 between 8.00 am – 5.00 pm weekdays to arrange repair by the nearest Makita Service Agent at no charge.